Abstract
We have demonstrated enhancement of coherent anti-Stokes Raman spectroscopy signals in liquid benzene contained in dielectric waveguide capillaries with angular phase-matching conditions. Enhancement factors as high as 130 were observed relative to a single crossing. These were measured for capillaries of various cross sections as a function of length. The maximum enhancement we observed was in a 50-μm × 50-μm × 292-mm capillary with a sample volume of 0.75 μl. Signals increased steadily with capillary length and showed the same dependence on pump-beam crossing angle (phase-matching conditions) as in bulk samples.
© 1979 Optical Society of America
Full Article | PDF ArticleMore Like This
K. A. Marko and L. Rimai
Opt. Lett. 4(7) 211-213 (1979)
Robert J. Hall, John A. Shirley, and Alan C. Eckbreth
Opt. Lett. 4(3) 87-89 (1979)
Daniel V. Murphy, Marshall B. Long, Richard K. Chang, and Alan C. Eckbreth
Opt. Lett. 4(6) 167-169 (1979)